Skip to content

NAS and UniFi appliances

Host IP What Monitoring NetBox
nas01 10.0.3.34 UniFi UNAS Pro 4 HTTPS probe device (Storage)
nas02 10.0.3.35 Synology DSM node_exporter (Docker) + HTTPS probe, dashboard Synology NAS device (Storage)
nas03 10.0.3.38 Synology DSM node_exporter (Docker) + HTTPS probe, dashboard Synology NAS device (Storage)
unvr 10.0.3.127 UniFi UNVR (Protect) HTTPS probe device (NVR)
usw-aggregation-hvn 10.0.0.239 USW-Lite-8 Aggregation ping + unpoller device (Switch)
usw-xg-hvn 10.0.0.213 USW-XG ping + unpoller device (Switch)
unifi-os-server 10.0.3.30 UniFi OS Server LXC (controller for the two switches) unpoller (UniFi dashboards) VM

Inventory: external group in inventory/00-static.yml (nb_* vars feed NetBox via roles/netbox_sync/tasks/external.yml).

Synology (nas02, nas03)

playbooks/nas.yml (Semaphore template nas) logs in as root over SSH and runs prom/node-exporter in Docker (Container Manager) with host network/PID and / mounted read-only, so volumes, md RAID, disks and temperatures are visible. A DSM update can remove the container: the alert NasExporterDown fires, rerun the template.

Prerequisites per NAS: Container Manager installed; Semaphore's public key in /root/.ssh/authorized_keys; host key pinned in the Semaphore CT's known_hosts.

Alerts: NasRaidDegraded (md array missing/failed disk), NasExporterDown, plus the generic disk-full and probe alerts. Grafana: Synology NAS (homelab folder) and Node Exporter Full.

UniFi

unpoller runs on the Prometheus LXC (:9130, job unpoller) when the vault has vault_unifi_poller_user / vault_unifi_poller_password: a View Only local admin on the UniFi OS Server. Create it in UniFi OS Server → Admins & Users → Create New → Restrict to local access only, role Network View Only, then:

scripts/vault-set.py vault_unifi_poller_user unpoller
scripts/vault-set.py vault_unifi_poller_password      # prompts, nothing in shell history

and run the monitoring template. Dashboards imported: UniFi-Poller Network Sites (11311), USW Insights (11312), UAP Insights (11314), Client Insights (11315).

The other Ubiquiti devices on the LAN (Switchberging2, Switchhok, Switchmeterkast, U6-ProWoonkamer, U6-Litegang, UVC-G3-Flex) show up as clients on this controller, i.e. they are adopted by another controller; add them to unifi_devices once that is known.